Answer
![David.Sundin](https://data3.answerbase.com/answerbase/11365/UserFiles/User2348549/profileImage2348549.jpg?637090785480000000)
Oct 14, 2021 - 09:35 AM
The bulk modulus of AC-140 is a function of temperature and pressure applied to the test cell. We have the following data at 40C:
Applied Pressure AC-140 Bulk Modulus, PSIA
2000 psig 234073
4000 psig 243693
6000 psig 253335
8000 psig 262999
10000 psig 272683
Applied Pressure AC-140 Bulk Modulus, PSIA
2000 psig 234073
4000 psig 243693
6000 psig 253335
8000 psig 262999
10000 psig 272683