The bulk modulus of AC-140 is a function of temperature and pressure applied to the test cell. We have the following data at 40C:
Applied Pressure AC-140 Bulk Modulus, PSIA
2000 psig 234073
4000 psig 243693
6000 psig 253335
8000 psig 262999
10000 psig 272683
Applied Pressure AC-140 Bulk Modulus, PSIA
2000 psig 234073
4000 psig 243693
6000 psig 253335
8000 psig 262999
10000 psig 272683